Serum Free Light Chain Assay and Kapa/Lamtha Ratio: Performance in Patients With Monoclonal Gammopathy-High False Negative Rate for Kapa/Lamtha Ratio

Gurmukh Singh

Abstract


Background: Serum free light chain assay (SFLCA) and kapa/lamtha ratio, and protein electrophoretic methods are used in the diagnosis and monitoring of monoclonal gammopathies.

Methods: Results for serum free light chains, serum and urine protein electrophoreses and immunofixation electrophoreses in 468 patients with a diagnosis of monoclonal gammopathy were compared. The results of the two methods were graded as concordant, non-concordant or discordant with the established diagnoses to assess the relative performance of the methods. Results ofkapa/lamtha ratio in samples with monoclonal protein detectable by electrophoretic methods were also analyzed.

Results: Protein electrophoreses results were concordant with the established diagnoses significantly more often thankapa/lamtha ratio. The false negative rate forkapa/lamtha ratio was higher than that for electrophoretic methods. Kapa/lamtha ratio was falsely negative in about 27% of the 1,860 samples with detectable monoclonal immunoglobulin. The false negative rate was higher in lesions with lambda chains (32%) than those with kappa chains (24%). The false negative rate forkapa/lamtha ratio was over 55% in samples with monoclonal gammopathy of undetermined significance. Even at first encounter, the false negative rates forkapa/lamtha ratios for monoclonal gammopathy of undetermined significance, smoldering myeloma and multiple myeloma were 66.98%, 23.08%, and 30.15%, respectively, with false negative rate for lambda chain lesions being higher.

Conclusions: Electrophoretic studies of serum and urine are superior to SFLCA and kapa/lamtha ratio. Abnormalkapa/lamtha ratio,per se, is not diagnostic of monoclonal gammopathy. A normalkapa/lamtha ratio does not exclude monoclonal gammopathy. False negative rates for lesions with lambda chain are higher than those for lesions with kappa chains. Electrophoretic studies of urine are underutilized. Clinical usefulness and medical necessity of SFLCA andkapa/lamtha ratio is of questionable value in routine clinical testing.




J Clin Med Res. 2017;9(1):46-57
doi: https://doi.org/10.14740/jocmr2802w


Keywords


Monoclonal gammopathy; Serum free light chain assay; Kappa/lambda ratio; Serum protein electrophoresis; Serum protein immunofixation electrophoresis; Urine protein electrophoresis; Urine protein immunofixation electrophoresis

Full Text: HTML PDF
 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Journal of Clinical Medicine Research, monthly, ISSN 1918-3003 (print), 1918-3011 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.jocmr.org   editorial contact: editor@jocmr.org     elmer.editorial2@hotmail.com
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.