The Utility of Echocardiography in Estimating Fluid Responsiveness

Nnedindu Asogwaa, Marc Assaadb, d, Joanne Linga, Gennifer Wahbah Makhoula, Halim El Hagec

aDepartment of Medicine, Staten Island University Hospital, Staten Island, NY 10305, USA
bDepartment of Pulmonary and Critical Care, Carilion Clinic Virginia Tech School of Medicine, Roanoke, VA 24014, USA
cDepartment of Pulmonary and Critical Care, Staten Island University Hospital, Staten Island, NY 10305, USA
dCorresponding Author: Marc Assaad, Department of Pulmonary and Critical Care, Carilion Clinic Virginia Tech School of Medicine, Roanoke, VA 24014, USA

Manuscript submitted January 19, 2024, accepted March 20, 2024, published online April 30, 2024
Short title: Fluid Responsiveness Estimation Methods
doi: https://doi.org/10.14740/jocmr5114

Abstract▴Top 

Assessing the volume status in critically ill patients is the key to maintain the stability of the hemodynamics; however, it can be challenging to view the complexity of cases and the diversity of shock etiology. Multiple noninvasive means have been used to study the effectiveness of volume resuscitation, but none of them have been used as gold standard. We aim to illustrate the most used techniques: left ventricular outflow tract velocity time integral versus inferior vena cava compressibility index, and highlight their limitations and strengths. These tools are both operator-dependent and might be affected by several factors including ventilator settings.

Keywords: Fluid responsiveness; Echocardiography; Stroke volume; Cardiac output; Inferior vena cava; Left ventricular outflow tract

Introduction▴Top 

Establishing hemodynamic stability in critically ill patients optimizes their clinical outcome. Intravenous fluid therapy is a common treatment modality in critical care medicine and is essential in maintaining hemodynamic stability [1]. However, in the critical care setting, the etiology of hemodynamic instability is often multifactorial. Critically ill patients require accurate monitoring and estimation as to when fluid therapy is warranted. This is often difficult as clinical parameters such as blood pressure, urine output and heart rate may not detect early signs of hypovolemia [2]. Furthermore, fluid therapy in a patient that is not fluid responsive has shown to increase morbidity and mortality [3]. Fluid responsiveness is classically defined as an increase in stroke volume (SV) by greater than 10% after rapid volume infusion as well as a change in cardiac output (CO) [4, 5].

Body▴Top 

Standard of care in determining fluid responsiveness in patients

Traditionally, central venous pressure (CVP) monitoring and mean arterial pressure (MAP) were used to assess when invasive fluid therapy was indicated in critically ill patients. However, multiple studies have shown that they are not accurate in predicting fluid responsiveness among these patients [6]. Marik et al conducted a meta-analysis which enforced that CVP should not be used to guide fluid therapy. Methods like pulse-pressure change by radial arterial line, fluid challenge, left ventricular outflow tract (LVOT) velocity time integral (VTI) on echocardiogram, carotid doppler flow on transesophageal echocardiogram (TEE), inferior vena cava (IVC) collapsibility index (IVCCI) have been proposed as alternate modes of determining fluid management [7]. Additionally, a prospective observational study suggested that the right subclavian vein variation during a respiratory cycle matches up with IVCCI and can be used to speculate fluid responsiveness [8].

Noninvasive cardiac imaging and most common techniques

Several techniques for assessing fluid responsiveness and CO have been validated. Although it is beyond the scope of this paper, we would like to list some of these described tools.

CVP or right atrial pressure is used to be considered one of the parameters that we used to judge whether fluids should be administered or not. A large number of studies have shown that the positive predictive value of CVP for fluid responsiveness is low [9]. Similar findings were reported in regards of using pulmonary artery occlusion pressure (PAOP) as an accurate predictor of preload even in healthy subjects. Like CVP, PAOP should not be used to decide on fluid administration [9]. Passive leg raise (PLR) has been used as a trial of reversible fluid challenge. It is applicable in spontaneous breathing, low tidal volumes (TVs), and is not affected by irregular cardiac rhythms. The test starts in semi recumbent position, then the head is lowered, and the legs are raised. The effect is expected in 1 to 5 min. Several studies, even in ventilated patients, have shown that PLR successfully predicts a response to volume administration. However, this technique might be limited in increased intra-abdominal pressure, musculoskeletal problems and may require a special hospital bed [10]. Pulse pressure variation (PPV) is also another famous technique, reported in one of the most influential studies to be effective in predicting fluid responsiveness. However, its use is limited in ventilated patients with TV < 8 mL/kg, irregular rhythm, right ventricular dysfunction or those who are spontaneously breathing [11].

Echocardiography has become the most common method of estimating fluid responsiveness in the intensive care unit by monitoring CO [12]. The LVOT VTI has been the most studied technique [13]. McGregor et al conducted a study with LVOT VTI as the standard and compared the technique to other methods of noninvasive CO monitoring which include common carotid artery blood flow monitoring and plethysmography using the vascular unloading technique. Although IVCCI does not estimate CO, this method was also included in the analysis [13]. This analysis showed variability in the ability of noninvasive cardiac imaging evaluating SV and CO when compared with LVOT VTI in estimating fluid responsiveness [13].

LVOT effectiveness

Left ventricular systolic function is monitored using LVOT. An increase in LVOT VTI can be extrapolated to an increase in SV which subsequently means an increase in CO [14]. Using the echocardiogram, the VTI is measured before and after fluid challenge or a PLR which is equivalent to 250 - 500 mL fluid bolus. A greater than 10% change in VTI after the fluid challenge is an indicator of fluid responsiveness. Wang et al looked at the effect of LVOT VTI variation rate in assessing fluid responsiveness in ventilated patients with septic shock. They utilized the variation in hemodynamic parameters like SV, cardiac index, and pulse pressure after volume expansion test, comparing it to the LVOT VTI variation. They found that there was a positive relation between the change in these parameters and the LVOT VTI after the volume expansion test. LVOT VTI was found to have extremely high sensitivity and specificity in predicting fluid responsiveness. However, this study only included sedated and ventilated septic patients [3].

Similarly, Asta et al performed a study looking at LVOT VTI in spontaneous breathing patients after major abdominal surgery and found that LVOT VTI variation of more than 10% during the respiratory cycle correlated with fluid responsiveness. There are limitations when using dynamic parameters in spontaneous breathing patients such as TV, variation in intrathoracic pressure as well as abdominal wall contraction [15]. However, these limitations did not pose any significant difference. In this study, the variation in abdominal wall contraction was limited as these patients were in the early post-operative period [15].

Blancas et al did not find a definite association between LVOT VTI and SV. They suggest the use of this method in correlation with other tools of hemodynamic monitoring [16]. Another study that looked at LVOT VTI using TEE, found a weak correlation between using LVOT VTI measured by TEE and SV index calculated using a pulmonary artery catheterization. This study was only done in patients undergoing cardiac surgery [17]. Factors that influence the accuracy of LVOT VTI are usually in cases with LVOT obstruction [16]. Low preload states as well as dynamic obstruction can influence these readings. It is also important to note that it does not consider right ventricular dysfunction [3].

IVC diameter

The IVC diameter dilates during inspiration and contracts during expiration. The IVC distensibility index takes into account the percentage variation of the IVC during the respiratory cycle [18]. Orso et al conducted a meta-analysis on the accuracy of using variation in IVC diameter as a predictor of fluid responsiveness [18]. Multiple studies varied in analyzing the possible correlation between the IVC and fluid responsiveness [19, 20]. Some studies were able to show that the IVCCI was a strong predictor of fluid responsiveness and other studies were not [19, 21]. However, these variations were seen across different patient populations. There was variation in the accuracy of the IVCCI in patients examined in the emergency department and the operating rooms versus in the intensive care unit [18].

Orso et al conducted a meta-analysis and found that in septic patients the distensibility index was more reliable in predicting fluid responsiveness as compared to surgical patients given the component of increased abdominal pressure affecting the reliability of the IVCCI [18].

Multiple studies looked at the flatness of IVC on computed tomography (CT) scan and compared it to lactate level and predictability of shock. Some studies found a relationship between flat IVC and indication for massive transfusion [22], while others did not show any correlation with IVC flatness and fluid responsiveness. However, CT scans are static and ultrasound technique is dynamic which allows better assessment of the variation [23].

During passive ventilation, the IVC diameter increases during inspiration as the pressure in the right atria increases and decreases during expiration. In mechanically ventilated patients, IVCCI has been shown to be an accurate measure of fluid responsiveness [15, 24, 25] and both inspiratory and expiratory IVC correlated significantly with CVP [24]. However, Si et al found that it was an accurate measure of fluid responsiveness in ventilated patients when the TV was ≥ 8 mL/kg and positive end expiratory pressure (PEEP) was ≤ 5 cm water (cm H2O). When these parameters were not accounted for, they found that the IVCCI was a poor predictor of fluid responsiveness [26]. Similarly, He et al demonstrated that IVC distensibility index is affected by TV and is most accurate at TV of 9 mL/kg [27]. On the other hand, an observational study on 79 critically ill patients who were on mechanical ventilation showed that LVOT VTI variations can be taken into account when predicting fluid responsiveness at PEEP level ranging between 0 and 10 cm H2O [28].

Given the variation with spontaneous breathing, there has been heterogeneity in the studies involving this patient population. In spontaneous breathing patients, the variation in the IVCCI greater than 40% has been shown to be a strong indicator for fluid responsiveness [15]. However, a variability of less than 40% does not strongly indicate that a patient would not be considered fluid responsive and leaves room for clinical assessment [29]. Some studies have shown fluid responsiveness with IVC variability of > 27% and even as low as 20% variation. In other words, fluid responsiveness should not be excluded in cases with small variation in IVC [15].

Limitations

Noninvasive cardiac imaging has limitations in the sense that it is mostly dependent on the sonographic skill, and the breathing motion can affect the ability to obtain accurate visualization of the LVOT VTI as well as the IVC. The use of LVOT VTI is limited in patients with aortic regurgitation, dilated left ventricle, and atrial fibrillation. Thus, the use of noninvasive cardiac imaging and the interpretation of the results in patients with structural heart disease should be done cautiously.

Another limitation of the LVOT VTI would be chest wall abnormalities which is commonly seen in our practice. Concave shaped chest wall, or anterior chest wall deformity such as pectus excavatum can affect echocardiographic measurements such as SV. Therefore, LVOT VTI should be put in relation to body surface area and chest wall confirmation [30].

LVOT VTI seems to be less affected by mechanical ventilation parameters (TV and PEEP) as compared to IVCCI which seems to be more reliable in cases of structural heart disease. IVCCI technique has more limitations when it comes to mechanical ventilation, respiratory cycle, and abdominal wall surgeries.

Lastly, these methods are of importance in evaluating volume status in hypovolemic or septic state. Whereas in cardiogenic, anaphylactic, mixed or undifferentiated shock, these modalities are not effective in estimating volume status.

Conclusion▴Top 

In this review, we described the effectiveness and limitations of LVOT VTI and IVCCI in predicting fluid responsiveness. The use LVOT VTI appears to be a superior technique in estimating fluid responsiveness especially when it comes to intubated patients as compared to IVCCI which showed more variations. In conclusion, the use of the noninvasive cardiac imaging techniques in conjunction with other tools of hemodynamic monitoring and clinical judgment are recommended to improve the accuracy of fluid responsiveness estimation.

Acknowledgments

We would like to thank the Research Department at Staten Island University Hospital for helping us finalize this paper.

Financial Disclosure

This research received no grants from any funding campaign, the authors received no financial support.

Conflict of Interest

The authors declare that there is no conflict of interest.

Author Contributions

All authors have participated in writing this manuscript. Doctor El Hage and Doctor Assaad are responsible for concept and editing. Doctor Assaad is responsible for supervision and writing. Doctor Asogwa, Ling and Wahbah Makhoul did the literature review and the writing.

Data Availability

The authors declare that data supporting the findings of this study are available within the article.


References▴Top 
  1. Finfer S, Myburgh J, Bellomo R. Intravenous fluid therapy in critically ill adults. Nat Rev Nephrol. 2018;14(9):541-557.
    doi pubmed
  2. Vincent JL. Fluid management in the critically ill. Kidney Int. 2019;96(1):52-57.
    doi pubmed
  3. Wang J, Zhou D, Gao Y, Wu Z, Wang X, Lv C. Effect of VTILVOT variation rate on the assessment of fluid responsiveness in septic shock patients. Medicine (Baltimore). 2020;99(47):e22702.
    doi pubmed pmc
  4. Xu J, Peng X, Pan C, Cai S, Zhang X, Xue M, Yang Y, et al. Fluid responsiveness predicted by transcutaneous partial pressure of oxygen in patients with circulatory failure: a prospective study. Ann Intensive Care. 2017;7(1):56.
    doi pubmed pmc
  5. Eskesen TG, Wetterslev M, Perner A. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness. Intensive Care Med. 2016;42(3):324-332.
    doi pubmed
  6. Cecconi M, Aya HD. Central venous pressure cannot predict fluid-responsiveness. Evid Based Med. 2014;19(2):63.
    doi pubmed
  7. Marik PE, Cavallazzi R. Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med. 2013;41(7):1774-1781.
    doi pubmed
  8. Kumar A, Mahendran M, Hari S, Ranjan P, Soneja M, Wig N. Subclavian vein collapsibility as a predictor of fluid responsiveness in spontaneously breathing hypotensive patients. J Assoc Physicians India. 2022;70(4):11-12.
    pubmed
  9. Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32(3):691-699.
    doi pubmed
  10. Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36(9):1475-1483.
    doi pubmed
  11. De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31(4):517-523.
    doi pubmed
  12. Desai N, Garry D. Assessing dynamic fluid-responsiveness using transthoracic echocardiography in intensive care. BJA Educ. 2018;18(7):218-226.
    doi pubmed pmc
  13. McGregor D, Sharma S, Gupta S, Ahmed S, Harris T. Emergency department non-invasive cardiac output study (EDNICO): an accuracy study. Scand J Trauma Resusc Emerg Med. 2020;28(1):8.
    doi pubmed pmc
  14. Blanco P. Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings. Ultrasound J. 2020;12(1):21.
    doi pubmed pmc
  15. Maciuliene A, Maleckas A, Krisciukaitis A, Maciulis V, Macas A. Variability of left ventricle outflow tract VTI during breathing cycle may predict fluid responsiveness in the postoperative period for non-cardiac spontaneously breathing patients. Clin Pract. 2017;14(5):43956026.
  16. Blancas R, Martinez-Gonzalez O, Ballesteros D, Nunez A, Lujan J, Rodriguez-Serrano D, Hernandez A, et al. Lack of correlation between left ventricular outflow tract velocity time integral and stroke volume index in mechanically ventilated patients. Med Intensiva (Engl Ed). 2019;43(2):73-78.
    doi pubmed
  17. Isogai H, Ogasawara O. Is there a correlation between left ventricular outflow tract velocity time integral and stroke volume index in patients undergoing cardiac surgery? Cureus. 2022;14(7):e27257.
    doi pubmed pmc
  18. Orso D, Paoli I, Piani T, Cilenti FL, Cristiani L, Guglielmo N. Accuracy of ultrasonographic measurements of inferior vena cava to determine fluid responsiveness: a systematic review and meta-analysis. J Intensive Care Med. 2020;35(4):354-363.
    doi pubmed
  19. Ismail MT, El-Iraky AA, Ibrahim EEA, El Kammash TH, Abou-Zied AE. Comparison of inferior vena cava collapsibility and central venous pressure in assessing volume status in shocked patients. Afr J Emerg Med. 2022;12(3):165-171.
    doi pubmed pmc
  20. Chardoli M, Ahmadi M, Shafe O, Bakhshandeh H. Inferior vena cava diameter as a guide in hypotensive patients for appropriate saline therapy: an observational study. Int J Crit Illn Inj Sci. 2018;8(3):160-164.
    doi pubmed pmc
  21. Zengin S, Al B, Genc S, Yildirim C, Ercan S, Dogan M, Altunbas G. Role of inferior vena cava and right ventricular diameter in assessment of volume status: a comparative study: ultrasound and hypovolemia. Am J Emerg Med. 2013;31(5):763-767.
    doi pubmed
  22. Chien CY, Yan JL, Han ST, Chen JT, Huang TS, Chen YH, Wang CY, et al. Inferior vena cava volume is an independent predictor of massive transfusion in patients with trauma. J Intensive Care Med. 2021;36(4):428-435.
    doi pubmed
  23. Miraflor E, Yeung L, Strumwasser A, Sadjadi J, Victorino GP. Correlation between IVC dimensions and volume status on CT scan. J Surg Res. 2011;170(2):291-296.
    doi pubmed
  24. Schefold JC, Storm C, Bercker S, Pschowski R, Oppert M, Kruger A, Hasper D. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. J Emerg Med. 2010;38(5):632-637.
    doi pubmed
  25. Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30(9):1740-1746.
    doi pubmed
  26. Si X, Xu H, Liu Z, Wu J, Cao D, Chen J, Chen M, et al. Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis. Anesth Analg. 2018;127(5):1157-1164.
    doi pubmed
  27. He F, Li X, Thapa S, Li C, Luo J, Dai W, Liu J. Evaluation of volume responsiveness by pulse pressure variability and inferior vena cava dispensability index at different tidal volumes by mechanical ventilation. Braz J Med Biol Res. 2019;52(9):e8827.
    doi pubmed pmc
  28. Zhou G, Zhang H, Wang X, Liu D. Variation of left ventricular outflow tract velocity time integral at different positive end-expiratory pressure levels can predict fluid responsiveness in mechanically ventilated critically ill patients. J Cardiothorac Vasc Anesth. 2022;36(8 Pt B):3101-3108.
    doi pubmed
  29. Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, Quintard H, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012;16(5):R188.
    doi pubmed pmc
  30. Sonaglioni A, Nicolosi GL, Trevisan R, Lombardo M, Grasso E, Gensini GF, Ambrosio G. The influence of pectus excavatum on cardiac kinetics and function in otherwise healthy individuals: a systematic review. Int J Cardiol. 2023;381:135-144.
    doi pubmed


This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.


Journal of Clinical Medicine Research is published by Elmer Press Inc.

 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Journal of Clinical Medicine Research, monthly, ISSN 1918-3003 (print), 1918-3011 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.jocmr.org   editorial contact: editor@jocmr.org     elmer.editorial2@hotmail.com
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.