Possible Impact of Spinal Anesthesia and Phenylephrine on Sublingual Microcirculation of Cesarean Delivery Patients

Ronald B. Georgea, b, d, Colin Boyda, Dolores McKeena, b, Islam Saleh Abdoc, Christian Lehmannb

aDepartment of Women’s and Obstetric Anesthesia, IWK Health Centre, Halifax, NS, Canada
bDepartment of Anesthesia, Pain Management, and Perioperative Medicine, Dalhousie University, Halifax, NS, Canada
cDepartment of Anesthesia, Intensive care and Perioperative Medicine, Masaryk Hospital, Usti nad Labem, Czech Republic
dCorresponding Author: Ronald B. George, Department of Women’s & Obstetric Anesthesia, IWK Health Centre, 5850/5980 University Avenue, PO Box 9700, Halifax, NS, B3K 6R8, Canada

Manuscript submitted February 15, 2019, accepted May 13, 2019
Short title: Cesarean Spinal Anesthesia Microcirculation
doi: https://doi.org/10.14740/jocmr3778

Abstract▴Top 

Background: This study was a proof of concept of a novel means to evaluate microcirculatory changes during spinal anesthesia for cesarean delivery. It sought to examine the distributive circulatory effects of spinal anesthesia and evaluate the impact of phenylephrine administration on the microcirculation of these women.

Methods: After Research Ethics Board approval, healthy, non-laboring pregnant women with singleton, term pregnancies scheduled for elective cesarean delivery were recruited. Participants were randomly assigned to receive either phenylephrine infusion or phenylephrine bolus. Spinal anesthesia was standardized. A sidestream dark-field (SDF) MicroScan® video microscope was applied to the sublingual mucosa to obtain microcirculation videos in five different visual fields. Videos were made before and after spinal anesthesia. The resultant videos were analyzed randomly and blindly. The mean microvascular flow index (MFI) values were compared before and after spinal anesthesia. The difference in MFI following spinal anesthesia was compared between phenylephrine infusion and bolus groups.

Results: Thirty-two patients were recruited for the study; 22 patients had complete video sets for analysis. Baseline characteristics were similar between the two groups, including preoperative hemodynamics. There were no significant differences between pre- and post-spinal MFI. The post-spinal MFI within the infusion group (mean ± standard deviation: 2.74 ± 0.21) was not significantly different from the bolus group (2.56 ± 0.42, P = 0.22).

Conclusion: Despite theoretical physiological implications of spinal anesthesia and phenylephrine on the microcirculation, significant alteration of the MFI was not observed between pre- and post-spinal anesthesia (within group). Additionally, despite an eight-fold larger phenylephrine dose for continuous infusion prophylaxis used in this group of women, this did not result in a significant alteration of the microcirculation compared to those who received phenylephrine treatment for hypotension (between groups).

Keywords: Spinal anesthesia; Microcirculation; Phenylephrine; Sidestream dark-field imaging; Obstetric anesthesia

Introduction▴Top 

Maternal hypotension is the most common side effect of spinal anesthesia and is a result of physiologic changes to the macrocirculation [1, 2]. Spinal anesthesia causes sympathetic nervous system blockade and reduction of systemic vascular resistance. Maternal hypotension is associated with adverse side effects such as maternal nausea and vomiting and fetal acidosis from reduced placental blood flow (secondary to maternal hypotension). If maternal hypotension is treated and/or prevented with vasopressors, specifically the direct α-adrenergic agonist, phenylephrine, fetal outcomes as assessed by umbilical arterial and venous pH are significantly improved [1, 3-6]. These fetal improvements are likely due to the vasopressor effect on the maternal microcirculation and its subsequent impact on macrocirculation and central hemodynamics [7, 8].

The microcirculation, consisting of the smallest vessels of the vasculature, is responsible for delivery of oxygen and regulation of blood pressure. Microcirculation by definition includes capillaries, small arterioles and venules which connect immediately adjacent to capillaries to form the pre- and post-capillary units [9]. Currently, our understanding of changes to the microcirculation in pregnant women receiving spinal anesthesia for cesarean delivery is limited. The impact of spinal anesthesia and phenylephrine on the microcirculation of pregnant women using sidestream dark-field (SDF) technology is yet to be reported. This novel study is the first to analyze the microcirculatory response in patients who receive spinal anesthesia and receive two variations of phenylephrine administration for treatment. Abdo et al stated that SDF imaging is a novel approach to the measurement of microcirculation and has a wide application of usefulness within the clinical field [10].

SDF imaging is a stroboscopic light-emitting diode (LED) ring-based imaging modality allowing microscopic assessment of microcirculatory capillary density and perfusion in clinical settings [11-13]. This is achieved by an analysis of the moving cells in the images, which permits the quantitative measurement of red blood cell flow in the capillaries. SDF imaging consists of a light guide surrounded by a 530 nm LED, a wavelength of light that is absorbed by the hemoglobin of red blood cells, which allows for their observation as dark cells flowing in the microcirculation. It permits quantification of microvascular blood flow using the microvascular flow index (MFI) and vessel density.

The primary objective of this research was to examine the physiologic impact of spinal anesthesia and the influence of prophylactic phenylephrine infusion (PEI) versus phenylephrine bolus (PEB) administration on the distributive circulation. This objective was measured by SDF imaging on the sublingual microcirculation of pregnant subjects. The SDF imaging was performed pre- and post-spinal anesthesia, prior to neonatal delivery during cesarean delivery. We also compared the influence of PEI administered for prophylaxis to PEB administered for treatment of hypotension on sublingual microcirculation following administration of spinal anesthesia. We hypothesized that the combined impact of spinal anesthesia and phenylephrine on the microcirculation would be a reduced MFI, vascular density and proportion of perfused vessels.

Materials and Methods▴Top 

With Institutional Research Ethics Board approval (IWK REB #1010276), ASA physical status II pregnant women with singleton gestation at gestational age > 36 weeks scheduled for elective cesarean delivery under spinal anesthesia were recruited. This study was conducted in compliance with the ethical standards of the IWK Health Centre on human subjects as well as with the Helsinki Declaration. Patients were recruited at the IWK Health Centre, Halifax, NS, Canada. Exclusion criteria included: women who were in labor, had a body mass index (BMI) > 35 kg/m2, type 1 diabetes mellitus, hypertensive disease or cardiac disease, an allergy to phenylephrine or any other standardized medication, were smokers, or had any caffeine intake within 6 h of SDF measurement. Patients were withdrawn if they were unable to complete the SDF imaging or if they had a failed spinal anesthetic (i.e. block lower than T6 dermatome or greater than T2 dermatome). Block height was determined with a blunt tip needle approximately 5 min after spinal anesthetic was administered.

After informed consent was obtained, patients were randomly assigned to one of two groups: PEI or PEB. Patient allocation was performed by opening opaque envelopes containing the patient’s group and study ID number prepared by research staff. Randomization was according to a computer-generated randomization order (Random.org). Maternal age, height, weight, BMI and gestational age were recorded. Blood pressure and heart rate were measured in the supine position with left uterine displacement. Baseline systolic blood pressure (SBP) was determined by calculating the mean of three consecutive SBP measurements taken in the preoperative area.

All patients received antacid prophylaxis with 30 mL sodium citrate and were transferred to the operative room. Spinal anesthesia was clinically administered at the L3-L4 interspace in the sitting position using 12 mg of hyperbaric bupivacaine with 15 µg of fentanyl and 150 µg of preservative free morphine. Patients were then immediately laid supine with left uterine displacement to minimize aortocaval compression and hypotension. All patients received a crystalloid fluid co-load immediately after the spinal. This was gravity delivered with a goal of 1,000 mL prior to delivery. The dermatomal level affected was determined 5 min after spinal anesthesia by the attending anesthesiologist and recorded. Blood pressure was measured at 1-min intervals for the first 15 min immediately after the spinal anesthetic, then every 2.5 min until the time of delivery. Hypotension was defined as the higher blood pressure of either SBP < 80% of baseline or < 90 mm Hg. Hypertension was defined as SBP > 120% of baseline.

Patients in the PEI group had a PEI of 30 µg/min started immediately after administration of spinal anesthesia in conjunction with crystalloid fluid co-loading. Participants in the PEB group were also given the same crystalloid co-load after the spinal was administered. Those in the PEB group who experienced hypotension (range predefined) were treated with 50 - 100 µg boluses of phenylephrine (5 - 10 mg boluses of ephedrine second line therapy). The number and type of interventions needed to maintain the blood pressure in the patients’ target range were documented. The total amount of intravenous fluid administered, as well as the total cumulative dose of vasopressors administered during the study period, was also recorded.

The initial SDF measurements were completed in the obstetric preoperative area with the patient supine with left uterine displacement, mirroring the position in the operating room. The second set of paired post images were then completed 10 min after spinal anesthesia was initiated. Trained research staff recorded all noninvasive SDF images using the MicroScan® video microscope (MicroVision Medical, Amsterdam, The Netherlands). The SDF device was equipped with a sterile LED probe cap and was gently applied to the sublingual oral mucosa to avoid pressure artifact. Steady images of at least 10 s duration were recorded and stored digitally on a research laptop. Digital recordings of five different visual fields were obtained for each participant, with minimal intervals between recordings.

Research staff quantified blood flow using semi-quantitative analysis software (AVA 3, MicroVision Medical) which was developed specifically for the MicroScan® video microscope. Video clips were analyzed by the same, single research staff according to the established guidelines [14]. The video images, which contain no identifiable information, were analyzed at random to prevent coupling between images. An investigator not involved with the video analysis completed the randomization of the videos with a randomization table generated on Random.org separate from the participant allocation randomization. Demographic and clinical data were collected and presented as mean (standard deviation), median (interquartile range), or counts as appropriate using SPSS Statistic 21 software package (IBM Corporation, Armonk, NY, USA).

The primary outcome was MFI pre- and post-spinal anesthesia. Additionally, comparison of the impact of vasopressors administered either PEI vs. PEB post-spinal anesthesia on MFI was assessed. A power calculation was performed for the difference between two dependent (pre- and post-spinal) and secondarily, two independent (PEI and PEB groups) means of MFI using data from our recently completed assessment of maternal microcirculation [15]. Using G*Power (version 3.0.10, University of Dusseldorf) with a standard deviation of 0.2, the calculated effect size is 1.472 (10% change in capillary density) (alpha 0.05, power 0.9). Eight (dependent) or 24 (independent) patients (12 per group) result in the appropriate power. The mean MFI values of all patients were compared before and after spinal anesthesia using paired Student’s t-tests.

Results▴Top 

Thirty-two participants were recruited and randomly assigned to either receive a PEI or PEB. Of these, 22 patients had complete video sets available for pre- and post-spinal analysis and of these, assigned to either receive a PEI (n = 11) or PEB if treatment was required (n = 11).

Baseline characteristics were similar between the two groups, including preoperative hemodynamics (Table 1). Intraoperative characteristics are presented in Table 2. The mean dose of phenylephrine in the PEI group was 1,603 ± 470 µg with four patients who experienced hypotension requiring the rate of PEI to be increased. Hypotensive characteristics were identified if a patient’s SBP decreases to < 90 mm Hg, or a decrease by 20% in SBP. Of those four, the infusion rate was increased prior to imaging in three patients, and after imaging in one patient. One patient received an additional 10 mg ephedrine to treat hypotension. Nine patients in the PEB group received vasopressors during the 10-min evaluation period with mean doses of 200 ± 142 µg of phenylephrine and 13 ± 6 mg of ephedrine.

Table 1.
Click to view
Table 1. Demographic Characteristics
 

Table 2.
Click to view
Table 2. Intraoperative Characteristics
 

The pre-spinal MFI (2.78 ± 0.27) was not significantly different than the post-spinal MFI (2.65 ± 0.34) for all participants (mean difference (MD): 0.13, 95% CI: -0.03 to 0.29, P = 0.11, Fig. 1). There were no significant differences between pre- and post-spinal MFI in the within-group comparisons (Fig. 2a (PEI) and b (PEB)). The between-group comparison of post-spinal MFI for the PEI group (2.74 ± 0.21) was not significantly different compared to the post-spinal PEB group (2.56 ± 0.42) (MD: 0.18, 95% CI: -0.11 to 0.48, P = 0.22, Fig. 3). There were no differences in total vessel density, perfused vessel density, or the proportion of perfused vessels between the PEI and PEB groups following administration of spinal anesthesia (Table 3).

Figure 1.
Click for large image
Figure 1. Mean MFI measurements pre- and post-spinal anesthesia entire cohort. Thick, solid line in the box represents the mean, whiskers represent the 95% confidence interval and solid dots are participants. MFI: microvascular flow index.

Figure 2.
Click for large image
Figure 2. MFI measurements pre- and post-spinal anesthesia for the (a) phenylephrine infusion and (b) phenylephrine bolus groups.

Figure 3.
Click for large image
Figure 3. Post-spinal MFI between infusion and bolus groups was not significantly different (P = 0.22). Thick, solid line in the box represents the mean, whiskers represent the 95% confidence interval and solid dots are participants. MFI: microvascular flow index.

Table 3.
Click to view
Table 3. Additional Post-Spinal Microcirculation Measures
 

Within the PEB group, seven participants received vasopressors prior to imaging, two participants received vasopressor after imaging and two did not receive any vasopressors. Subgroup analyses were conducted comparing the four subjects who did not receive vasopressors prior to imaging, to the seven subjects who did. This showed there was no significant difference between the mean MFI pre- (MD: -0.06, 95% CI: -0.38 to 0.25, P = 0.66) and post-spinal (MD: 0.17, 95% CI: -0.45 to 0.79, P = 0.56).

Discussion▴Top 

This study was designed to improve our understanding of how spinal anesthesia and phenylephrine influence maternal microcirculation. Our results showed no statistically significant difference in MFI after administration of spinal anesthesia (Fig. 2). This suggests that spinal anesthesia may have a limited impact on sublingual microcirculation. These findings are congruent with a recent report from our group showing that epidural analgesia may not impact sublingual microcirculation in laboring women [16].

Prophylactic infusion of phenylephrine did not result in a statistically significant alteration of the microcirculation compared to those who only required PEBs to treat spinal anesthesia-induced hypotension (Fig. 2). Indeed, this is despite an average eight-fold greater dose of phenylephrine administered to the PEI group compared to the PEB group (1,603 µg vs. 200 µg). Maier et al showed differences in sublingual MFI using SDF; however, they administered phenylephrine at an infusion rate of 1.4 µg/kg/min with an average patient mass of 79.6 kg [17]. Therefore, this would be on average a three times greater dose than the baseline dose provided in the current study. Additionally, Maier et al titrated their dose to increase perfusion pressure by 20 mm Hg, whereas we have attempted only to prevent a 20% decrease in SBP [17].

Our inability to detect changes within the systemic vascular resistance and observe MFI differences pre- and post-spinal anesthesia may have been confounded by a lack of statistical power, the vasoconstrictive properties of phenylephrine and the clinical necessity to treat hypotension particularly in the PEB group. This inability is particularly evident in the planned pre- and post-spinal anesthesia comparison of the PEB group, to directly assess physiologic impact of spinal anesthesia where seven of 11 patients required support from vasopressors to maintain their blood pressure prior to SDF imaging. The timing and rate of vasopressor intervention in this group was necessary to ensure the safety and comfort of our patients throughout the course of our study protocol. Despite this clinical trial challenge, we did not adjust the study protocol to delay vasopressor administration or tolerate any more than a 20% decrease in SBP from baseline before treating appropriately.

While others have used periungal capillaries as a surrogate marker of capillary bed changes in the uterus and placenta in pregnant patients [18], we have previously suggested that sublingual microcirculation may be a useful indicator of those outcomes [15]. Our inability to detect any changes to MFI after administration of spinal anesthesia suggests that these observed hypotensive changes may not impact systemic microcirculation and therefore may not impact placental microcirculation. Similarly, we did not find any differences in sublingual MFI after prophylactic infusion of phenylephrine despite the direct alpha-adrenergic agonism and expected vasoconstriction. Therefore, it must be considered that the amount of drug administered in the current study is simply below a physiologic threshold where microcirculatory changes are detectable by SDF. Accordingly, our results suggest that as much as 30 µg/min dose of phenylephrine does not have any strong influence on sublingual microcirculation and therefore placental blood flow.

An alternative explanation for the similar MFI measurements before and after the administration of spinal anesthesia is that the SDF probe is not sensitive enough to detect changes in MFI [9]. Given the hemodynamic perturbations that were observed after administration of spinal anesthesia, and that 13 of our 22 patients experienced hypotension, it is reasonable to assume that there were some alterations in the microvasculature; yet this trend did not correlate with MFI measured by the SDF probe.

Our group has previously shown no significant differences in MFI among pregnant women before and after administration of epidural analgesia, despite the potential for hypotension [16]. The next generation of microcirculatory microscope, incident dark field (IDF) imaging, includes technical improvements. However, despite improvements of IDF to detect total vessel density and proportion of perfused vessels, it has not been shown to have the same superior capacity to detect changes in MFI in transcutaneous microcirculatory measurements among infants [19].

Due to technical issues with SDF video quality, we were unable to capture the required 12 participants per group (n = 11) as determined a priori to detect a significant difference pre-post spinal anesthesia between PEI and PEB groups. The technical challenges included suboptimal imaging of the capillaries due to motion-induced image blurring by movement of the OPS device, the tissue and/or flowing red blood cells. Also, in larger vessels, especially during continuous flow, it is difficult to observe the granular nature of flowing blood cells due to blurring of images. These technical challenges introduce difficulties in measuring blood flow velocities in these vessels. For these reasons, recruitment was halted at 32 subjects.

While providing important insight, this study was limited by its clinical nature and the necessity to treat hypotension for safety and symptomatic control. These necessary safety protocols limited out ability to control for the amount and timing of phenylephrine patients received and therefore it can be difficult to isolate the influence of spinal anesthesia on microcirculation when confounded by vasopressor. This influence should be further explored using a gravid animal model, where maintenance of normal blood pressure and symptom management is not a requirement, thus allowing a better comparison. Additionally, we have not attempted to measure the contribution of macrovascular changes in the response to spinal anesthesia or phenylephrine. The measurements may have helped us to correlate their influence with hemodynamic changes. Lastly, the hemoglobin level, which was not measured, appears to be a determinant of the capillary network and may impact the sublingual capillary density [20]. Future studies incorporating a positive control, such as a large vessel, and measuring hemoglobin levels may elucidate the influence of vasopressors or fluid resuscitation.

In conclusion, we have found no difference in MFI before or after administration of spinal anesthesia, nor between groups receiving phenylephrine as a prophylactic infusion or in required treatment boluses. These findings suggest that neither spinal anesthesia nor PEI at 30 µg/min have a strong influence on microcirculatory blood flow. By extension, consideration of these practices likely does not pose a significant risk when providing regional anesthesia and hemodynamic support during cesarean delivery.

Acknowledgments

We would like to acknowledge the hard-working research staff of the Department of Women’s & Obstetric Anesthesia, without whom our programs of research would not be successful.

Financial Disclosure

This work was supported by a category B grant (#12608) from the IWK Health Centre.

Conflict of Interest

The authors have no conflict of interest to disclose.

Informed Consent

All patients provided written informed consent prior to study participation.

Author Contributions

Ronald George contributed to the conception and design of the study, data analysis and writing of the manuscript. Colin Boyd contributed to the data collection, data analysis and writing of the manuscript. Dolores McKeen contributed to the design of the study, data interpretation and editing of the manuscript. Islam Saleh Abdo contributed to the design of the study, data interpretation and editing of the manuscript. Christian Lehmann contributed to the design of the study, data interpretation and editing of the manuscript.


References▴Top 
  1. Lee JE, George RB, Habib AS. Spinal-induced hypotension: Incidence, mechanisms, prophylaxis, and management: Summarizing 20 years of research. Best Pract Res Clin Anaesthesiol. 2017;31(1):57-68.
    doi pubmed
  2. Habib AS. A review of the impact of phenylephrine administration on maternal hemodynamics and maternal and neonatal outcomes in women undergoing cesarean delivery under spinal anesthesia. Anesth Analg. 2012;114(2):377-390.
    doi pubmed
  3. Allen TK, George RB, White WD, Muir HA, Habib AS. A double-blind, placebo-controlled trial of four fixed rate infusion regimens of phenylephrine for hemodynamic support during spinal anesthesia for cesarean delivery. Anesth Analg. 2010;111(5):1221-1229.
    doi pubmed
  4. Cooper DW, Carpenter M, Mowbray P, Desira WR, Ryall DM, Kokri MS. Fetal and maternal effects of phenylephrine and ephedrine during spinal anesthesia for cesarean delivery. Anesthesiology. 2002;97(6):1582-1590.
    doi pubmed
  5. Ngan Kee WD, Khaw KS, Lau TK, Ng FF, Chui K, Ng KL. Randomised double-blinded comparison of phenylephrine vs ephedrine for maintaining blood pressure during spinal anaesthesia for non-elective Caesarean section*. Anaesthesia. 2008;63(12):1319-1326.
    doi pubmed
  6. Ngan Kee WD, Lee A, Khaw KS, Ng FF, Karmakar MK, Gin T. A randomized double-blinded comparison of phenylephrine and ephedrine infusion combinations to maintain blood pressure during spinal anesthesia for cesarean delivery: the effects on fetal acid-base status and hemodynamic control. Anesth Analg. 2008;107(4):1295-1302.
    doi pubmed
  7. den Uil CA, Lagrand WK, Spronk PE, van der Ent M, Jewbali LS, Brugts JJ, Ince C, et al. Low-dose nitroglycerin improves microcirculation in hospitalized patients with acute heart failure. Eur J Heart Fail. 2009;11(4):386-390.
    doi pubmed
  8. Elbers PW, Ozdemir A, van Iterson M, van Dongen EP, Ince C. Microcirculatory imaging in cardiac anesthesia: ketanserin reduces blood pressure but not perfused capillary density. J Cardiothorac Vasc Anesth. 2009;23(1):95-101.
    doi pubmed
  9. Massey MJ, Shapiro NI. A guide to human in vivo microcirculatory flow image analysis. Crit Care. 2016;20:35.
    doi pubmed
  10. Abdo I, George RB, Farrag M, Cerny V, Lehmann C. Microcirculation in pregnancy. Physiol Res. 2014;63(4):395-408.
  11. De Backer D, Creteur J, Dubois MJ, Sakr Y, Vincent JL. Microvascular alterations in patients with acute severe heart failure and cardiogenic shock. Am Heart J. 2004;147(1):91-99.
    doi pubmed
  12. De Backer D, Creteur J, Preiser JC, Dubois MJ, Vincent JL. Microvascular blood flow is altered in patients with sepsis. Am J Respir Crit Care Med. 2002;166(1):98-104.
    doi pubmed
  13. Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG. Orthogonal polarization spectral imaging: a new method for study of the microcirculation. Nat Med. 1999;5(10):1209-1212.
    doi pubmed
  14. De Backer D, Hollenberg S, Boerma C, Goedhart P, Buchele G, Ospina-Tascon G, et al. How to evaluate the microcirculation: report of a round table conference. Critical Care. 2007;11(5):101.
    doi pubmed
  15. George RB, Munro A, Abdo I, McKeen DM, Lehmann C. An observational assessment of the sublingual microcirculation of pregnant and non-pregnant women. Int J Obstet Anesth. 2014;23(1):23-28.
    doi pubmed
  16. George RB, DesRoches J, Abdo I, Lehmann C. Maternal microcirculation and sidestream dark field imaging: a prospective assessment of the association between labour pain and analgesia on the microcirculation of pregnant women. Clin Hemorheol Microcirc. 2015;60(4):389-395.
    doi pubmed
  17. Maier S, Hasibeder WR, Hengl C, Pajk W, Schwarz B, Margreiter J, Ulmer H, et al. Effects of phenylephrine on the sublingual microcirculation during cardiopulmonary bypass. Br J Anaesth. 2009;102(4):485-491.
    doi pubmed
  18. Ohlmann P, Jung F, Mrowietz C, Alt T, Alt S, Schmidt W. Peripheral microcirculation during pregnancy and in women with pregnancy induced hypertension. Clin Hemorheol Microcirc. 2001;24(3):183-191.
  19. van Elteren HA, Ince C, Tibboel D, Reiss IK, de Jonge RC. Cutaneous microcirculation in preterm neonates: comparison between sidestream dark field (SDF) and incident dark field (IDF) imaging. J Clin Monit Comput. 2015;29(5):543-548.
    doi pubmed
  20. Sharawy N, Hussein A, Hossny O, Refaa A, Saka A, Mukhtar A, Whynot S, et al. Effects of haemoglobin levels on the sublingual microcirculation in pregnant women. Clin Hemorheol Microcirc. 2016;64(2):205-212.
    doi pubmed


This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.


Journal of Clinical Medicine Research is published by Elmer Press Inc.

 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Journal of Clinical Medicine Research, monthly, ISSN 1918-3003 (print), 1918-3011 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.jocmr.org   editorial contact: editor@jocmr.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.